RAMS for Scaffold Erection Near Power Lines — UK

UK construction-safety guidance by the Riskora Editorial Team

Scaffold erected near overhead lines is one of the very few activities HSE inspectors treat as a presumption of prosecution after any contact incident. The combination of long conductive tubes, lift-and-swing manoeuvres, and HV potential gradients means a near-miss is often indistinguishable from a fatality — current can arc to a tube up to 2m from a 132kV line in damp conditions without direct contact. The framework is well established: HSE GS6 (Avoiding Danger from Overhead Power Lines), the Electricity at Work Regulations 1989, and TG20:21 from the NASC for the scaffold design itself. What rejected RAMS for this scope have in common is that they treat the power line as a generic hazard and skip the three steps the DNO actually wants to see: written enquiry, written response with proposed exclusion distance, and a documented method that respects it. This page covers what a UK scaffold-near-OHL RAMS must contain to satisfy the DNO, the principal contractor, and the NASC-trained scaffold designer.

Under 5 minutesNo training requiredPDF downloadBuilt for UK contractors

Example RAMS

RAMS for Scaffold Erection Near Power Lines — UK

  • OHL identification: line operator (DNO), nominal voltage, conductor height under maximum sag, span direction, and the GS6 minimum safe distance applicable
  • Written DNO enquiry reference number and the DNO's written response (exclusion distance, isolation feasibility, supervisor requirement)
  • Scaffold design reference: NASC TG20:21 compliance sheet or bespoke design with engineer's signature; loading category; tie pattern; sheeting/netting flag
  • Exclusion zone marking on site: Heras fence with bunting, ground markings, exclusion overlay on the site plan
Create a scaffold erection near power lines RAMS free

No card required · 1 lifetime safety document · Upgrade when you need more

When This Document Is Required

Required wherever scaffold standards, transoms, ledgers, materials being lifted, or any operative position will come within the exclusion zone of an overhead conductor as defined by HSE GS6 Table 1 (typically 9m horizontal from any conductor up to 33kV, more for HV). Under the Electricity at Work Regulations 1989 Reg 14, work on or near live conductors is prohibited unless it is unreasonable to disconnect them AND suitable precautions are in place AND the worker is competent. CDM 2015 Reg 13 requires the principal contractor to plan, manage and monitor. The DNO (UK Power Networks, SSEN, National Grid Electricity Distribution, etc.) must be engaged in writing before erection — most will require sight of the RAMS and may require temporary line shutdown, insulated barriers, or live-line cover. The Work at Height Regulations 2005 and TG20:21 also apply for the scaffold design itself.

What Must Be Included

  • OHL identification: line operator (DNO), nominal voltage, conductor height under maximum sag, span direction, and the GS6 minimum safe distance applicable
  • Written DNO enquiry reference number and the DNO's written response (exclusion distance, isolation feasibility, supervisor requirement)
  • Scaffold design reference: NASC TG20:21 compliance sheet or bespoke design with engineer's signature; loading category; tie pattern; sheeting/netting flag
  • Exclusion zone marking on site: Heras fence with bunting, ground markings, exclusion overlay on the site plan
  • Lift planning: appointed person, banksman, lift method (telehandler vs forklift vs crane), boom-reach envelope check against OHL exclusion
  • Insulation barriers where the DNO permits work inside the exclusion zone — 'goalpost' specification (typically <5m height, with bunting), insulating mats over conductors if specified
  • Weather thresholds: stop work above wind speeds defined in NASC SG4 (gusts >17 m/s for handling components), no work in heavy rain or lightning
  • PPE: Class 3 hi-vis, EN 397 helmet with chinstrap, dielectric gloves where direct work inside the zone is unavoidable, harness for any scaffold not yet fitted with edge protection
  • Operative competence: CISRS card with photo and grade, scaffolder logbook, OHL toolbox-talk record
  • Emergency arrangements: 999 + DNO emergency number, contact-with-line response (do not touch the casualty, isolate at source via DNO, treat as a serious injury), nearest A&E with burns capability
  • Permit-to-work referenced, named competent-person sign-off, post-erection inspection and scaffold tag fitted before handover

Common Mistakes to Avoid

  • Assuming voltages can be judged from line height or pole construction — only the DNO's written response is acceptable evidence of voltage and required clearance
  • Specifying 'safe distance maintained' without naming the distance or its source — GS6 Table 1 distances must be quoted in the RAMS, not implied
  • Treating the exclusion zone as a 2D ground line — it is a 3D envelope around the conductor including sag and side-sway in wind
  • Lifting scaffold tubes with a telehandler whose maximum boom-reach intersects the exclusion zone without a banksman with a clear line of sight to the boom tip
  • Skipping the DNO written enquiry on the assumption that 'it's only an LV line' — even 230V can be fatal and the DNO enquiry process is a Reg 14 evidence requirement
  • Erection in marginal weather where SG4 wind thresholds would normally stop work, on the basis that 'we only have a few more lifts to go'

Example Scenario

A scaffolding subcontractor in Reading is asked to erect a 3-lift independent scaffold to a flank wall that runs 7m below an 11kV overhead line. The GS6 exclusion is 6m horizontal from the conductor at maximum sag, putting the scaffold inside the zone. Using Riskora, the contracts manager selects the Scaffolding preset, adds the OHL hazard, references the DNO's written response (SSEN reference logged, exclusion confirmed at 6m, insulating cover quoted for installation by the DNO at the contractor's cost), specifies a goalpost barrier at 4m height at both ends of the scaffold run, names the appointed person and the banksman with their CISRS and CPCS card numbers, sets the wind stop-threshold to NASC SG4 limits, and references the TG20:21 design sheet. The 12-page RAMS exports in 7 minutes, is submitted to the principal contractor and to SSEN, and live-line cover is installed two days ahead of scaffold erection. No incidents, no rework.

Create Your RAMS in Minutes

Select your trade, pick your hazards, and generate a structured document — no training required.

Create a scaffold erection near power lines RAMS free

No card required · 1 lifetime safety document · Paid tiers add branding, sign-off and audit trails

Or learn more about the platform: See plans and one-off options →

Built for real job scenarios · Designed for UK contractors and competent-person review

All documents should be reviewed by a competent person before use on site.

Free safety-document builder

Create a scaffold erection near power lines RAMS free — preview before sign-up

Generate a preview first. Sign up only when you want to save, edit or export.

Final RAMS must be reviewed and approved by a competent person before use.

Riskora is an assistive document preparation tool. All documents generated must be reviewed, verified, and approved by a competent person before use on site. Riskora does not replace professional safety judgment, and no output should be treated as a legal compliance guarantee.