Installing electrical systems in a live environment — an occupied building, an operational factory, or a building with energised circuits — is one of the most hazardous activities in the electrical trade. One wrong connection, one missed isolation, or one unexpected back-feed can result in electrocution, arc flash, or fire. Your RAMS must address the specific challenges of working alongside live systems and other building users.

Under 5 minutesNo training requiredPDF downloadBuilt for UK contractors

Example RAMS

RAMS for Electrical Installation in a Live Environment — UK

  • Description of electrical works and their interface with live systems
  • Identification of live circuits and systems in the work area
  • Isolation procedures and lock-out/tag-out arrangements
  • Live working justification (if applicable) per Regulation 14
Create a electrical installation live environment RAMS free

No card required · 1 lifetime safety document · Upgrade when you need more

When This Document Is Required

The Electricity at Work Regulations 1989 require that work on or near electrical systems is carried out safely and that risks are assessed. Regulation 14 prohibits live working unless it is unreasonable to work dead — and the justification must be documented. Under CDM 2015, electrical installation in a live environment is a high-risk activity requiring specific RAMS. Building operators, facilities managers, and principal contractors will all require RAMS before permitting electrical works in their occupied spaces.

What Must Be Included

  • Description of electrical works and their interface with live systems
  • Identification of live circuits and systems in the work area
  • Isolation procedures and lock-out/tag-out arrangements
  • Live working justification (if applicable) per Regulation 14
  • Arc flash risk assessment and PPE requirements
  • Safe distances from live conductors (GS38 guidance)
  • Testing procedures using calibrated instruments with proving units
  • Coordination with building operator and other trades
  • Emergency procedures for electric shock, arc flash, and fire
  • Communication plan with building occupants

Common Mistakes to Avoid

  • Assuming circuits are dead without testing with a proving unit
  • Carrying out live work without formal Regulation 14 justification
  • Not assessing arc flash risk at distribution boards and panels
  • Using non-insulated tools when working near live conductors
  • Failing to coordinate with the building operator on planned isolations
  • Not informing building occupants about electrical works and potential outages

Example Scenario

An electrical contractor in Manchester is installing new power distribution on a floor of an occupied office building. The existing distribution boards remain energised, and the building's fire alarm and emergency lighting systems must remain operational throughout. Using Riskora, the project electrician generates a RAMS covering isolation sequences, live working justification for specific tasks, arc flash PPE requirements, and coordination with the building's facilities team — all in under 5 minutes.

Create Your RAMS in Minutes

Select your trade, pick your hazards, and generate a structured document — no training required.

Create a electrical installation live environment RAMS free

No card required · 1 lifetime safety document · Paid tiers add branding, sign-off and audit trails

Or learn more about the platform: See plans and one-off options →

Built for real job scenarios · Designed for UK contractors and competent-person review

All documents should be reviewed by a competent person before use on site.

Free safety-document builder

Create a electrical installation live environment RAMS free — preview before sign-up

Generate a preview first. Sign up only when you want to save, edit or export.

Final RAMS must be reviewed and approved by a competent person before use.