UK (RAMS) example document — Two-Storey Rear Extension — 14 Birchwood Lane, Reading. Client: Mr & Mrs A. Whitfield (Private Client). Site: 14 Birchwood Lane, Reading, RG1 5JT. Scope: Construction of a two-storey rear extension (6.4m × 4.2m) to an existing semi-detached dwelling. Works comprise breaking out of existing rear elevation, trench-fill foundations to 1.0m, traditional cavity blockwork to first floor, pre-stressed concrete lintels, timber roof structure with natural slate finish, plus alterations to existing rear wall to form structural opening with rolled steel joist (RSJ 203×102 UB23). Works programmed over 9 weeks with a peak site team of 6 operatives. Hazards assessed: Manual handling — blocks, lintels, plasterboard, Working at height — independent scaffold & roof structure, Buried services strike during excavation, Collapse of excavation / trench wall, Hand-arm vibration (HAVS) — breaking out, drilling, Silica dust — cutting blocks, brick, concrete, Vehicle/pedestrian segregation — narrow domestic street.

Example UK (RAMS) front cover produced by Riskora
Try the new compact mode. Same document, just more compact

Full version

Start Your RAMS Now — It's Free

Takes less than 5 minutes

No card required · 1 free PDF · Upgrade any time (completely free)

What should EV charger installation RAMS include?

An EV charger RAMS must cover the installation type (wall-mounted, pedestal, rapid charger), cable routing and trenching for supply cables, electrical isolation procedures at the distribution board, cable sizing and protection, the charger mounting method, commissioning and testing procedures, traffic management if installing in car parks or public areas, and the interface with the DNO if a new or upgraded supply is required.

EV Charger Installation Sits Across BS 7671, BS 8300 and HSG47 — Often On Live Premises

EV charger installation isn't a single trade — it's a stack of them. BS 7671:2018+A2:2022 Section 722 governs the electrical installation, including dedicated RCD/RDC-DD protection, OPDD detection and earth-fault loop checks under TT or TN-S supplies. The IET Code of Practice for EV Charging Equipment Installation (5th Edition, 2023) is the de facto competence reference, and OZEV grant schemes require it for installer authorisation. Where civils are needed — typical on commercial workplace and forecourt schemes — HSG47 underground service avoidance applies, with CAT/Genny scans before any breaking. BS 8300 governs accessible parking dimensions where chargers serve disabled bays, and on rapid (DC) installs the DNO interface, half-hourly metering and harmonics study under Engineering Recommendation P28/2 may be required. Many contractors aren't sure what a RAMS document actually requires, which leads to submissions being rejected.

How Riskora Helps

Riskora generates EV charger RAMS aligned with BS 7671 Section 722 and the IET Code of Practice. The builder prompts for charger type (Mode 2/3/4, AC 7.4 kW / 22 kW, DC 50 kW+), supply earthing arrangement (TT recommended, with PEN-fault detection on TN-C-S), dedicated final circuit specification, RCD/RDC-DD type, isolation procedure to HSG85 with GS38 test equipment, cable routing method (HSG47 service detection for buried runs), traffic management on live car parks (NRSWA Chapter 8 layouts), and the OZEV / TrustMark commissioning record. For more complex projects, you may also need a standalone risk assessment or method statement.

Who it's for

  • Electrical contractors installing domestic EV chargers under OZEV grant schemes
  • Commercial installers fitting workplace charging stations
  • Rapid charger installation teams working at fuel station forecourts
  • Property developers installing EV charging infrastructure on new-build estates
  • Local authority contractors installing on-street charging points

Key Risks and Considerations

  • Electrical shock — working on live circuits during connection
  • Cable strikes — trenching through car parks near existing services
  • Manual handling — charger units, cable drums, and concrete plinths
  • Working at height — wall-mounted installations requiring ladder or platform access
  • Vehicle movements — installing in active car parks
  • Silica dust — cutting concrete or masonry for cable routes
  • Slips and trips — trailing cables and open trenches in public areas

Key Features

  • EV charger installation presets (domestic, commercial, rapid)
  • Cable routing and trenching method templates
  • Electrical isolation and connection procedures
  • Traffic management for car park installations
  • Commissioning and testing checklists
  • Download to PDF

Example Structure (UK Standard)

  1. Installation type and charger specification
  2. Cable route design and method
  3. Electrical supply assessment (existing or new)
  4. Isolation procedure at distribution board
  5. Trenching or surface-mount cable routing
  6. Charger mounting and fixing method
  7. Hazard identification with risk ratings
  8. Control measures
  9. PPE requirements
  10. Traffic management (if applicable)
  11. Commissioning and testing procedure
  12. Emergency procedures

Common Questions Before Getting Started

Will this take long?

Under 5 minutes. Select your trade, pick hazards, download.

Is it complicated?

No training needed. The guided builder walks you through every step.

Do I need experience?

If you know what work you're doing, you can use Riskora.

Is it free to try?

Yes. The Free plan needs no card — generate, review and download one free PDF. Upgrade any time for branding, DOCX, sign-off and higher limits.

Create your RAMS in under 5 minutes

No onboarding or setup needed — start generating documents instantly

Try Riskora Free

No card required · 1 free PDF · Upgrade any time (completely free)

Used by contractors and professionalsNo learning curveDocuments ready in minutes
Built for real job scenarios · Used by UK contractors and professionals

All documents generated by Riskora should be reviewed by a competent person before use on site. Riskora provides structured templates — professional judgement is always required.

"EV charger installation is growing fast — and so are the incidents from installers who treat it as simple plug-and-play. The RAMS need to cover the trench, the cable, and the connection."
Inside the document

What your RAMS actually contains

Riskora builds a structured, client-facing document — not a generic AI paragraph. Every section is shaped around your job, your site and your team.

  • Hazards

    Task-specific hazards for the job, captured row by row — not a generic list pulled from an old RAMS.

  • Controls

    Control measures mapped to each hazard with residual risk scoring after controls are applied.

  • PPE

    PPE requirements tied to the activity and site, ready to brief to the team.

  • Method steps

    Step-by-step method statement structured around how the work is actually sequenced on site.

  • Emergency arrangements

    First aid, rescue plan, emergency contacts and site-specific escalation routes.

  • COSHH prompts

    Substance prompts when the work involves chemicals, dusts, fumes or sealants — flagged early, not missed at review.

  • Sign-off

    Operative sign-off captured against the document — names, dates and acknowledgement of the brief.

  • Version history

    Every change tracked so you can show what was issued, when, and which version the team signed.

  • Approval status

    Clear approval state on every document — draft, in review, approved, issued — visible across the team.

  • Audit trail

    Who created it, who reviewed it, who signed it. A complete trail you can hand to a principal contractor or auditor.

Before & after

From copied-and-pasted to site-specific

The reason RAMS get rejected is rarely the format — it's that the document is obviously generic. Riskora rebuilds it around this job, this site and this task.

Before

Generic template copied from an old job.

  • • Hazards and controls that don't match this site or task.
  • • Method steps written for a different sequence of work.
  • • No emergency arrangements specific to the location.
  • • Client flags it as generic and asks for a rewrite.
After

Site-specific document structured around this job, site and task.

  • • Hazards captured from the actual scope you pasted in.
  • • Method steps sequenced for how the work runs on site.
  • • Emergency arrangements and rescue plan tied to the location.
  • • Approved internally, briefed to the team, signed off and stored.
How it works

From job details to signed-off document

A four-step workflow used by contractors, consultants and safety teams to turn informal job details into client-ready safety paperwork.

  1. 1
    Paste job details

    Drop in a client email, a WhatsApp from the site manager, a scope of works or a tender note. Anything that describes the job.

  2. 2
    Riskora structures the document

    Riskora turns your brief into hazards, controls, method steps, PPE, emergency arrangements and COSHH prompts.

  3. 3
    Review, edit and download

    You stay in control of every section. Tweak anything, then download a clean PDF or share a link.

  4. 4
    Brief the team and record sign-off

    Brief operatives, capture their sign-off and keep a full audit trail of who signed which version.

Built for site reality

Built by people who've written this paperwork on real sites

Riskora is built by a founder with hands-on site and document experience — designed for contractors, consultants and safety teams who need to issue, brief and prove safety paperwork without losing a day to admin.

  • Built for contractors, consultants and teams
    Solo trades, principal contractors and in-house safety teams all run on the same workflow.
  • Supports multiple countries
    UK, Ireland, Australia, New Zealand, US and Canada — wording and document types match the local standard.
  • Not just documents
    Sign-off, approvals, version history and an audit trail — the management workflow around the paperwork.

Frequently Asked Questions

If you're working for a company or under a grant scheme (like OZEV), RAMS are expected. Even for private domestic work, RAMS demonstrate professional competence and are increasingly required by insurance providers and TrustMark-registered installers.

EV charger installers should hold appropriate electrical qualifications (18th Edition, 2391), be registered with a competent person scheme, and ideally hold manufacturer-specific training for the charger brand being installed.

If you're working in an active car park or public area, yes. Your RAMS should include traffic management arrangements — coning, barriers, signage — to separate the work area from vehicle and pedestrian traffic.

RAMS as a single document is not named in UK law, but the underlying duties are. The Management of Health and Safety at Work Regulations 1999 require a suitable and sufficient risk assessment, and CDM 2015 effectively requires a written method statement on most construction work. A RAMS satisfies both in one document, which is why principal contractors expect to see one.

Anyone competent to assess the risks of the work. Most subcontractors write their own RAMS for the tasks they carry out — formal qualifications aren't required, but the writer needs to genuinely understand the hazards, the controls and the site. Principal contractors will reject documents that look like they were written by someone who hasn't done the job.

Long enough to cover every hazard and method step honestly — usually 4 to 12 pages. Short, vague RAMS get rejected. Padded ones get skim-read on site, which defeats the point. Aim for specific, not lengthy.

At minimum: before each new site, after any significant change to the work, and after any near-miss or incident. Many principal contractors also expect a documented annual review even if nothing has changed.

Ready? It takes less than 5 minutes.

No training. No complex setup. Just select your trade and go.

Start Your RAMS Now — It's Free

No card required · 1 free PDF · Upgrade for branding, DOCX, sign-off and audit trails (completely free)

Already have a RAMS? Upload and rebuild it

References & Further Reading

Primary UK sources covering the legal and practical framework behind RAMS, risk assessments and method statements.

Free RAMS builder

Create your ev charger installation uk RAMS free — preview before sign-up

Generate a preview first. Sign up only when you want to save, edit or export.

Final RAMS must be reviewed and approved by a competent person before use.